Part #:MNS-2-WF-TS-HT-L03
Battery: 5 years
Range: 50 metres
Free Delivery
UK orders over £500
Money Back Guarantee
100% refund
Monnit wireless high temperature sensor use an RTD to accurately measure temperatures from -50°C to +370°C. Perfect for high temperature critical applications such as ovens, heaters, furnaces and boilers. User customization allows you to set the frequency of sensor readings and create notifications from the system when certain criteria have been met or exceeded.
* Actual range may vary depending on environment.
** Battery life is affected by reporting frequency (heartbeat), sensor type, Wi-Fi security type, distance from Wi-Fi router and other variables.
In order to program the sensor to connect to your wif-fi network, you will need a Wi-Fi programming cable and the free MoWi setup utility. The MoWi setup utility is currently available for Windows® PC's only. Mac and Linux are not currently supported!
High Temp - RTD / Thermistor Specifications |
|||
Sensing Element | DIN 43760 Class B | ||
Dissipation Constant @ 25°C | 2mW/°C | ||
RTD Temperature Range | -50°C to +370°C (-58°F to 700°F) | ||
RTD Accuracy | +/- 0.3°C @ 0°C | ||
Thermal Time Constant | 15 sec max. | ||
Wi-Fi Specifications |
|||
Battery Type | 2 Replaceable AA 1.5 V Batteries | ||
Max Operating Temperature Using AA Alkaline | -18°C to +55°C (0°F to +130°F) | ||
|
|||
Max Operating Temperature Using AA Lithium | -40°C to +85°C (-40°F to +185°F) | ||
Battery Life | Up to 5 years depending on sensor type, Wi-Fi security, distance from Wi-Fi router, reporting frequency and other variables. (Testing surpassed 90,000 transmissions until battery depletion.) | ||
Wi-Fi Security Standards | Open, WEP, WPA, WPA2 Security Standards | ||
Wi-Fi Security Programming | Via USB cable (sold separately) and downloadable PC software. | ||
Network Settings | Auto DHCP/DNS or Static | ||
Data Logging (iMonnit Basic) | On Wi-Fi disruption, unit will log the most recent 50 readings and transmit when Wi-Fi connection is re-established. | ||
Data Logging (iMonnit Premiere) | On Wi-Fi disruption, unit can log up to 50,000 readings and transmit when Wi-Fi connection is re-established. | ||
Power Consumption | 4uA sleep, 35mA active RX, 180mA TX (at +12dBm) | ||
Wi-Fi Data Rate | Auto configures to best rate for maximum range. | ||
LED Lights | Status / Activity | ||
Network Connectivity | Connects to hidden and visible Wi-Fi networks | ||
Wi-Fi Specifications |
|||
Operating Frequency | 802.11 b/g (2.412 - 2.484 GHz) | ||
Device Range | Up to 250 ft. (Typical to standard Wi-Fi devices) | ||
Certifications | FCC ID: T9J-RN171. IC: RSS-210 low-power communication device. CE ID: 0681. | ||
Contact us for volume quantity purchases of RoHS compliant product.
Monnit wireless high temperature sensor use an RTD to accurately measure temperatures from -50°C to +370°C. Perfect for high temperature critical applications such as ovens, heaters, furnaces and boilers. User customization allows you to set the frequency of sensor readings and create notifications from the system when certain criteria have been met or exceeded.
* Actual range may vary depending on environment.
** Battery life is affected by reporting frequency (heartbeat), sensor type, Wi-Fi security type, distance from Wi-Fi router and other variables.
In order to program the sensor to connect to your wif-fi network, you will need a Wi-Fi programming cable and the free MoWi setup utility. The MoWi setup utility is currently available for Windows® PC's only. Mac and Linux are not currently supported!
High Temp - RTD / Thermistor Specifications |
|||
Sensing Element | DIN 43760 Class B | ||
Dissipation Constant @ 25°C | 2mW/°C | ||
RTD Temperature Range | -50°C to +370°C (-58°F to 700°F) | ||
RTD Accuracy | +/- 0.3°C @ 0°C | ||
Thermal Time Constant | 15 sec max. | ||
Wi-Fi Specifications |
|||
Battery Type | 2 Replaceable AA 1.5 V Batteries | ||
Max Operating Temperature Using AA Alkaline | -18°C to +55°C (0°F to +130°F) | ||
|
|||
Max Operating Temperature Using AA Lithium | -40°C to +85°C (-40°F to +185°F) | ||
Battery Life | Up to 5 years depending on sensor type, Wi-Fi security, distance from Wi-Fi router, reporting frequency and other variables. (Testing surpassed 90,000 transmissions until battery depletion.) | ||
Wi-Fi Security Standards | Open, WEP, WPA, WPA2 Security Standards | ||
Wi-Fi Security Programming | Via USB cable (sold separately) and downloadable PC software. | ||
Network Settings | Auto DHCP/DNS or Static | ||
Data Logging (iMonnit Basic) | On Wi-Fi disruption, unit will log the most recent 50 readings and transmit when Wi-Fi connection is re-established. | ||
Data Logging (iMonnit Premiere) | On Wi-Fi disruption, unit can log up to 50,000 readings and transmit when Wi-Fi connection is re-established. | ||
Power Consumption | 4uA sleep, 35mA active RX, 180mA TX (at +12dBm) | ||
Wi-Fi Data Rate | Auto configures to best rate for maximum range. | ||
LED Lights | Status / Activity | ||
Network Connectivity | Connects to hidden and visible Wi-Fi networks | ||
Wi-Fi Specifications |
|||
Operating Frequency | 802.11 b/g (2.412 - 2.484 GHz) | ||
Device Range | Up to 250 ft. (Typical to standard Wi-Fi devices) | ||
Certifications | FCC ID: T9J-RN171. IC: RSS-210 low-power communication device. CE ID: 0681. | ||
Contact us for volume quantity purchases of RoHS compliant product.
12 month subscription to iMonnit Premiere monitoring service for your wireless sensor network.
The Monnit Wi-Fi programming cable allows you to connect your MoWi sensors to your PC via USB connection for initial configuration and Wi-Fi security setup via the MoWi Sensor Setup Utility.