Part #:MNS2-8-W2-VM-500-SW
Frequency:868 MHz (Euro)
Battery: 10 years
Range: 360 metres
Free Delivery
UK orders over £500
Money Back Guarantee
100% refund
ALTA wireless voltage meters are capable of measuring the voltage off another device, battery, or sensor. This sensor is capable of measuring voltage up to 500 VAC by connecting the leads on the sensor to the positive and ground terminals of the device being measured.
Examples of interfacing devices include, but are not limited to: Strain Gauge, Pressure Transducer, RTD, Thermistor, or Thermocouple, Piezo Electric sensors, Photoresistor, Industrial Accelerometer, any kind of variable resistor, any kind of sensor that outputs a voltage, etc. If the device being measured is passive, the user must supply their own excitation voltage, as the Monnit sensor is really just a “voltage observer”.
ALTA sensors offer 3 to 4 times the range of standard sensor platforms, extending non-line-of-sight reach to an exceptional 1,000+ feet through walls (12-14 walls typical). Using Frequency-hopping Spread Spectrum (FHSS) also allows ALTA sensors to have better interference immunity from other wireless devices.
Superior power management provides ALTA sensors with almost twice the battery life of Monnit’s standard wireless sensors.
Integrated on-board data storage allows ALTA sensors to store data messages if communication to a wireless gateway is disrupted (power outage, Internet outage, or out of range). Messages that can’t be delivered will be time-stamped and stored in memory (up to the last 3100 messages) until communication with the gateway is restored, at which point the messages will all be transmitted.
Over-the-air updates allow ALTA products to be updated remotely if new fixes or features become available.
The standard version of this sensor is powered by two replaceable 1.5 V AA sized batteries (included with purchase). This sensor is also available with a line power option. The line powered version of this sensor has a barrel power connector allowing it to be powered by a standard 3.0 - 3.8 V power supply (Included with Line Power option upgrade). The line powered version also uses two standard 1.5 V AA batteries as backup for uninterrupted operation in the event of line power outage.
Power options must be selected at time of purchase, as the internal hardware of the sensor must be changed to support the selected power requirements.
WARNING: Use caution when interfacing to the Monnit Wireless Voltage Meter. Negative voltages, any kind of AC Voltages, or DC Voltage exceeding 600V WILL DAMAGE the electronics of the Monnit Wireless Sensor. Monnit is not responsible for troubleshooting, replacing or reimbursing damages incurred by disregarding this warning.
* Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.
Voltage Meter Specifications |
|
Maximum Rated Input Voltage | Up to 600 VAC (will return a max of 500V in software) |
Full Scale Voltage | 0 - 500 VAC |
Accuracy | +/- 3% FS (User calibrated: +/- 1% FS) |
Resolution | 11 bit (single ended) |
Conversion Time | 228 µs |
ALTA AA Specifications |
|
Battery Type | 2 Replaceable AA 1.5 V Batteries |
Dimension | 4.375 in x 2.470 in x 1.12 in |
Supply Voltage | 2.0 - 3.8 V (2 x AA 1.5V Batteries or Optional Power Supply) |
Battery Life | At 1 hour heartbeat setting, included AA batteries will typically last 6-8 Years. ** |
Max Operating Temperature Using AA Alkaline | -18°C to 55°C (0°F to 130°F) |
Max Operating Temperature Using AA Lithium | -40°C to 60°C (-40°F to 140°F) |
Optimal Battery Operating Temperature | +10°C to +50°C (+50°F to +122°F) |
Enclosure Material | ABS |
ALTA 868 MHz Specifications |
|
Operating Frequency | 868 MHz Operating Frequency |
Certifications | CE Certified. Tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950. |
ALTA wireless voltage meters are capable of measuring the voltage off another device, battery, or sensor. This sensor is capable of measuring voltage up to 500 VAC by connecting the leads on the sensor to the positive and ground terminals of the device being measured.
Examples of interfacing devices include, but are not limited to: Strain Gauge, Pressure Transducer, RTD, Thermistor, or Thermocouple, Piezo Electric sensors, Photoresistor, Industrial Accelerometer, any kind of variable resistor, any kind of sensor that outputs a voltage, etc. If the device being measured is passive, the user must supply their own excitation voltage, as the Monnit sensor is really just a “voltage observer”.
ALTA sensors offer 3 to 4 times the range of standard sensor platforms, extending non-line-of-sight reach to an exceptional 1,000+ feet through walls (12-14 walls typical). Using Frequency-hopping Spread Spectrum (FHSS) also allows ALTA sensors to have better interference immunity from other wireless devices.
Superior power management provides ALTA sensors with almost twice the battery life of Monnit’s standard wireless sensors.
Integrated on-board data storage allows ALTA sensors to store data messages if communication to a wireless gateway is disrupted (power outage, Internet outage, or out of range). Messages that can’t be delivered will be time-stamped and stored in memory (up to the last 3100 messages) until communication with the gateway is restored, at which point the messages will all be transmitted.
Over-the-air updates allow ALTA products to be updated remotely if new fixes or features become available.
The standard version of this sensor is powered by two replaceable 1.5 V AA sized batteries (included with purchase). This sensor is also available with a line power option. The line powered version of this sensor has a barrel power connector allowing it to be powered by a standard 3.0 - 3.8 V power supply (Included with Line Power option upgrade). The line powered version also uses two standard 1.5 V AA batteries as backup for uninterrupted operation in the event of line power outage.
Power options must be selected at time of purchase, as the internal hardware of the sensor must be changed to support the selected power requirements.
WARNING: Use caution when interfacing to the Monnit Wireless Voltage Meter. Negative voltages, any kind of AC Voltages, or DC Voltage exceeding 600V WILL DAMAGE the electronics of the Monnit Wireless Sensor. Monnit is not responsible for troubleshooting, replacing or reimbursing damages incurred by disregarding this warning.
* Actual range may vary depending on environment.
** Battery life is determined by sensor reporting frequency and other variables.
Voltage Meter Specifications |
|
Maximum Rated Input Voltage | Up to 600 VAC (will return a max of 500V in software) |
Full Scale Voltage | 0 - 500 VAC |
Accuracy | +/- 3% FS (User calibrated: +/- 1% FS) |
Resolution | 11 bit (single ended) |
Conversion Time | 228 µs |
ALTA AA Specifications |
|
Battery Type | 2 Replaceable AA 1.5 V Batteries |
Dimension | 4.375 in x 2.470 in x 1.12 in |
Supply Voltage | 2.0 - 3.8 V (2 x AA 1.5V Batteries or Optional Power Supply) |
Battery Life | At 1 hour heartbeat setting, included AA batteries will typically last 6-8 Years. ** |
Max Operating Temperature Using AA Alkaline | -18°C to 55°C (0°F to 130°F) |
Max Operating Temperature Using AA Lithium | -40°C to 60°C (-40°F to 140°F) |
Optimal Battery Operating Temperature | +10°C to +50°C (+50°F to +122°F) |
Enclosure Material | ABS |
ALTA 868 MHz Specifications |
|
Operating Frequency | 868 MHz Operating Frequency |
Certifications | CE Certified. Tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950. |
12 month subscription to iMonnit Premiere monitoring service for your wireless sensor network.
The MonnitLink™ Ethernet gateway allows your Monnit Wireless Sensors to communicate with the iMonnit™ Online Wireless Sensor Monitoring and Notification System without the need for a PC. Simply plug this device into any open network port with internet connection and it will automatically connect with our online servers. The device will ..